THREE-PHASE TRIPLEX

The Power Partners Triplex overhead distribution transformer can be used to serve three-phase applications through 225 kVA. Triplex designs consist of three separate, single-phase, core-coil assemblies in one tank. Triplex overhead distribution transformers are often used to serve large motor loads where the motors are frequently started. Oil field pumping loads and some irrigation pumping loads should use only Triplex designs. Also, the Triplex transformer has international application where Dy5 and Dy11 phase displacement are required. ISO 9001: 2008 Certified

three-pahse-triplex

Wound core with step-lap joints for increased efficiency and lower noise levels.

Progressively wound coils with adhesive resins on insulating paper or conductors for increased short circuit strength, efficiency, and thermal strength.

CSP protection package available as an option for increased protection against surge currents, short circuits, and overloads:

  1. Primary protective links
  2. Surge arresters
  3. Secondary circuit breaker
  4. Secondary breaker operating handle with emergency overload reset and overload signal light

Three-point, core-coil bracing for increased mechanical strength.

Self-venting and resealing cover that eliminates the need for an auxiliary pressure-relief device and offers increased safety through higher tank withstand.

Durable, corrosion-resistant paint finish.

Cover has 15 kV dielectric insulation and increased resistance to corrosion. The cover is sloped 15, preventing water from collecting and thereby reducing the chances of corrosion and leaking.

  • 30 – 225 kVA
  • 65C rise
  • 60 Hz standard, 50 Hz optional
  • High voltages: 13,800 and below
  • Low voltages: 208Y/120, 240 x 480, and 480Y/277

Transformer BIL ratings:

PrimaryBIL
2400 T60 kV
4160 T60 kV
7200 T75 kV
8320 T75 kV
12,000 T95 kV
12,470 T95 kV
13,200 T95 kV
13,800 T95 kV

Standard Design Dimensions and Weights
All dimensions are approximate.

kVAHeight
Inches
(mm)
Width
Inches
(mm)
Depth
Inches
(mm)
Tank
Dia
Inches
(mm)
Distance
Between
Hanger
Brackets
Weight
Lbs.
(kg)
Shipping
Weight
Lbs.
(kg)
Oil
Gallons
(L)
High Voltages 4160GY/2400, 7200GY/4160, 8320GY/4800
3053
(1346)
26
(660)
25
(635)
17.5
(445)
11.25
(286)
760
(345)
805
(366)
40
(152)
4557
(1448)
26
(660)
25
(635)
17.5
(445)
23.25
(590)
915
(416)
960
(436)
45
(171)
7561
(1550)
33
(838)
28
(711)
20
(508)
23.25
(590)
1120
(509)
1165
(530)
60
(228)
112.561
(1550)
34
(864)
28
(711)
20
(508)
36
(914)
1540
(700)
1585
(720)
58
(220)
15073
(1854)
35
(889)
30
(762)
22
(559)
36
(914)
2455
(1116)
2525
(1148)
90
(342)
22576
(1930)
35
(889)
30
(762)
22
(559)
36
(914)
2650
(1205)
2745
(1248)
90
(342)
High Voltages 12,470GY/7200, 14,400GY/8320
3058
(1473)
23
(584)
25
(635)
17.5
(445)
11.25
(286)
760
(345)
805
(306)
40
(152)
4562
(1575)
23
(584)
25
(635)
17.5
(445)
23.25
(590)
920
(418)
965
(436)
45
(171)
7566
(1676)
29
(737)
28
(711)
20
(508)
23.25
(590)
1310
(595)
1355
(616)
60
(228)
112.566
(1676)
34
(864)
28
(711)
20
(508)
36
(914)
1540
(700)
1585
(720)
58
(220)
15078
(1981)
31
(787)
30
(762)
22
(559)
36
(914)
2470
(1123)
2540
(1155)
90
(342)
22581
(2057)
31
(787)
30
(762)
22
(559)
36
(914)
2650
(1205)
2745
(1248)
90
(342)
High Voltages 20,780GY/12,000, 21,590GY/12,470, 22,860GY/13,200, 23,900GY/13,800
3065
(1651)
23
(584)
25
(635)
17.5
(445)
11.25
(286)
940
(427)
985
(448)
45
(171)
4568
(1727)
26
(660)
28
(711)
20
(508)
23.25
(590)
12909
(586)
1340
(609)
60
(228)
7568
(1727)
26
(660)
28
(711)
20
(508)
23.25
(590)
1340
(609)
1365
(620)
58
(220
112.568
(1727)
34
(864)
28
(711)
20
(508)
36
(914)
1540
(700)
1585
(720)
58
(220)
15080
(2032)
31
(787)
30
(762)
22
(559)
36
(914)
2470
(1123)
2540
(1155)
90
(342)
22583
(2108)
31
(787)
30
(762)
22
(559)
36
(914)
2650
(1205)
2745
(1248)
90
(342)

For more information, contact Power Partners at 706/548-3121.